Accenture MDR Quick Start Guide for FreeRadius

This quick start guide will help Accenture MDR customers configure FreeRadius to send logs to the Log collection Platform (LCP).

The document includes the following topics:

Supported Versions

A list of supported versions is available in the Accenture MDR Supported Products List document (Accenture_MDR_Supported_Products_List.xlsx) which can be found at Accenture Portal - https://mss.accenture.com/PortalNextGen/Reports/Documents

Port Requirements

Table 1-1: Port requirements for LCP communication.

Source

Destination

Port

Description

FreeRadius 

LCP

514 (UDP) or

601 (TCP)

Default port

Configuring FreeRadius

  1. Login to the machine where the FreeRadius is hosted.

  2. Modify the file in below location

etc/freeradius/radius.conf

The "log" section of the radius.conf file is where the primary logging configuration for the FreeRADIUS server is located.

logdir = syslog Log_destination = syslog log{ destination = syslog syslog_facility = daemon stripped_names = no auth = yes auth_badpass = no auth_goodpass = no }

NOTE : The steps mentioned till now will ensure the logs goes to syslog directory within machine where freeradius is hosted. In order to send syslog to remote server, consult your system admin for configuration to send the syslog to remote server.

Below is one set of example for configuring syslog to remote server for linux machine :

3. Edit the file in below location

/etc/syslog.conf

# .=notice will log only authentication messages (L_AUTH) # <facility_name>.=notice @LCP-IP # .=err will log only module errors for radius #<facility_name>.=err @LCP IP # .* will log all messages in the same log file # <facility_name>.* @LCP IP

4. Restart the syslog daemon

LCP Configuration Parameters

Table 1-2: The FreeRadius event collector (Syslog - 3958) sensor properties to be configured by MDR are shown in the table.

Property

Default Value

Description

Protocol

UDP

The default protocol for syslog. The collector can also accept logs in TCP.

IP Address

Custom value

Logging device IP address mentioned in the Pre-Installation Questionnaire (PIQ).

Note: If the device sends logs using multiple interfaces, contact the Accenture Security MDR onboarding team.

Signatures

: Auth:

: Info:

: Warning:

: ERROR:

: Error:

MDR recommended signatures processed by the FreeRadius event collector.

Port Number

514

The default port number for syslog. For TCP, the default port is 601.



Legal Notice

Copyright © 2021 Accenture. All rights reserved.

Accenture, the Accenture Logo, and DeepSight Intelligence are trademarks or registered trademarks of Accenture in the U.S. and other countries. Other names may be trademarks of their respective owners.

The product described in this document is distributed under licenses restricting its use, copying, distribution, and decompilation/reverse engineering. No part of this document may be reproduced in any form by any means without prior written authorization of Accenture and its licensors, if any.

THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. ACCENTURE SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE.

The Licensed Software and Documentation are deemed to be commercial computer software as defined in FAR 12.212 and subject to restricted rights as defined in FAR Section 52.227-19 "Commercial Computer Software - Restricted Rights" and DFARS 227.7202, et seq. "Commercial Computer Software and Commercial Computer Software Documentation," as applicable, and any successor regulations, whether delivered by Accenture as on premises or hosted services. Any use, modification, reproduction release, performance, display or disclosure of the Licensed Software and Documentation by the U.S. Government shall be solely in accordance with the terms of this Agreement.