Accenture MDR Quick Start Guide for HPE OneView
This quick start guide will help Accenture MDR customers configure HPE OneView to send logs to the Log collection Platform (LCP).
This document includes the following topics:
Supported Versions
A list of supported versions is available in the Accenture MDR Supported Products List document (Accenture_MDR_Supported_Products_List.xlsx) which can be found in Accenture MDR Portal.
Port Requirements
Table 1-1: Port requirements for LCP communication.
Source | Destination | Port | Description |
HPE OneView | LCP | 514 (UDP) | Default port  |
Configuring HPE OneView
Login to HPE OneView Console. From the main menu, select Settings > Security.
Click the Edit icon in the Security panel or select Actions > Edit.
On the Edit Security screen, under Audit Log, enable Audit log forwarding.
Note : Audit log forwarding is disabled by default.
4. To add a destination system, click Add destination.
5. In the Add Destination page, provide the following details:
6. Fully Qualified Domain Name (FQDN) or IP address (IPv4 or IPv6) of LCP.
7. The port that the SIEM server is listening on. Default port: 514.
8. Click Add. To add more destination systems, click Add+. You can configure a maximum of three forwarding destinations.
9. Click OK. The configured forwarding destinations are displayed in the Actions > Audit Log pane.
10. Click Send test log entry.
11. Verify that the test entry is successfully forwarded to the LCP.
LCP Configuration Parameters
Table 1-2: The HPE OneView event collector (Syslog -4016) properties to be configured by Accenture are given in the table.
Property | Default Value | Description |
Protocol            | UDP | The default protocol for UDP |
IP  Address | HPE OneView IP address | The HPE One View host name or the IP address that forward syslog messages to the LCP. The default value '*' means all hosts. Possible values are:Â
Specify ANY, any, or * to allow any HPE OneView to send events to the LCP, or specify multiple computer names. Separate multiple computer names or IP addresses with commas. |
Signatures   | ci-audit-log | Accenture Security recommended signatures processed by the HPE OneView event collector. |
Port Number   | 514 | The default port for UDP |
Â
Legal Notice
Copyright © 2021 Accenture. All rights reserved.
Accenture, the Accenture Logo, and DeepSight Intelligence are trademarks or registered trademarks of Accenture in the U.S. and other countries. Other names may be trademarks of their respective owners.
The product described in this document is distributed under licenses restricting its use, copying, distribution, and decompilation/reverse engineering. No part of this document may be reproduced in any form by any means without prior written authorization of Accenture and its licensors, if any.
THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. ACCENTURE SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE.
The Licensed Software and Documentation are deemed to be commercial computer software as defined in FAR 12.212 and subject to restricted rights as defined in FAR Section 52.227-19 "Commercial Computer Software - Restricted Rights" and DFARS 227.7202, et seq. "Commercial Computer Software and Commercial Computer Software Documentation," as applicable, and any successor regulations, whether delivered by Accenture as on premises or hosted services. Any use, modification, reproduction release, performance, display or disclosure of the Licensed Software and Documentation by the U.S. Government shall be solely in accordance with the terms of this Agreement.