Accenture MDR Quick Start Guide for Epic System
This quick start guide will help Accenture MDR customers configure Epic System to send logs to the Log collection Platform (LCP).
The document includes the following topics:
Supported Versions
A list of supported versions is available in the Accenture MDR Supported Products List document (Accenture_MDR_Supported_Products_List.xlsx) which can be found in Accenture MDR Portal.
Port Requirements
Table 1-1: Port requirements for LCP communication.
Source | Destination | Port | Description |
Epic System | LCP | 601(TCP) | Default port |
Configuring Epic System
Note: Accenture MDR recommends that you coordinate with Epic support in order to accomplish the logging configuration.
If your instance of Interconnect does not have all Web services enabled, perform the following steps to run the required SendSIEMSyslogAudit service.
Access the Interconnect Configuration Editor (Start > Epic 2015 > Interconnect > [your instance] > Configuration Editor).
Select the Business Services form.
On the Service Category tab, select SendSIEMSyslogAudit.
Click Save.
To configure Epic System to send event logs to the LCP, follow the steps below.
Go to Epic System Definitions (%ZeUSTBL) > Security > Auditing Options > SIEM Syslog Settings.
Select the SIEM Syslog Configuration options:
In the Host text box, type the LCP_IP_Address.
In the Port text box, type the port number.
From the SIEM Format drop-drop list, select CEF (Common Event Format).
Set Syslog Ending Character to New Line “\n”
Return to the SIEM Syslog Settings menu.
Select SIEM Syslog and set it to Enabled.
LCP Configuration Parameters
Table 1-2: The Epic System event collector (3796 -Syslog) properties to be configured by MDR are shown in the table.
Property | Default Value | Description |
Protocol | TCP | The default protocol for syslog. Syslog relay is also supported. |
IP Address | Epic System interface IP address | Logging device IP address mentioned in the Pre-Installation Questionnaire (PIQ). Note: If the device sends logs using multiple interfaces, contact the Accenture MDR onboarding team. |
Signatures | |Epic|Security-SIEM| | MDR recommended signatures processed by the Epic System event collector. |
Port Number | 601 | The default port for Syslog. Note: The LCP can be configured to listen on a non-standard port, please advise the MDR onboarding team if this is a requirement. |
Legal Notice
Copyright © 2021 Accenture. All rights reserved.
Accenture, the Accenture Logo, and DeepSight Intelligence are trademarks or registered trademarks of Accenture in the U.S. and other countries. Other names may be trademarks of their respective owners.
The product described in this document is distributed under licenses restricting its use, copying, distribution, and decompilation/reverse engineering. No part of this document may be reproduced in any form by any means without prior written authorization of Accenture and its licensors, if any.
THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. ACCENTURE SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE.
The Licensed Software and Documentation are deemed to be commercial computer software as defined in FAR 12.212 and subject to restricted rights as defined in FAR Section 52.227-19 "Commercial Computer Software - Restricted Rights" and DFARS 227.7202, et seq. "Commercial Computer Software and Commercial Computer Software Documentation," as applicable, and any successor regulations, whether delivered by Accenture as on premises or hosted services. Any use, modification, reproduction release, performance, display or disclosure of the Licensed Software and Documentation by the U.S. Government shall be solely in accordance with the terms of this Agreement.