Accenture MDR Quick Start Guide for BeyondTrust Remote Support

This quick start guide will help Accenture MDR customers configure BeyondTrust Remote Support  to send logs to the Log collection Platform (LCP).

This document includes the following topics:

Supported Versions

A list of supported versions is available in the Accenture MDR Supported Products List document (Accenture_MDR_Supported_Products_List.xlsx) which can be found in Accenture MDR Portal.

Port Requirements

Table 1-1: Port requirements for LCP communication.

Source

Destination

Port

Description

BeyondTrust

LCP

514 (UDP)

Default port

 

Configuring BeyondTrust Remote Support

To enable syslog messages from the BeyondTrust Appliance, follow below steps.

  1. Login to the appliance.

  2. Navigate to /appliance > Security > Appliance Administration and scroll down to the Syslog section.

  3. Select Legacy BSD format in the Message Format drop down options and ensure LCP IP address in the Remote Syslog Server.

4.Click Submit.

LCP Configuration Parameters

Table 1-2: The BeyondTrust Remote Support event collector (Syslog -4001) properties to be configured by Accenture are given in the table.

Property

Default Value

Description

Protocol

UDP

Protocol that LCP uses to receive events.

Host Names/IP Addresses

*

The default value '*' means all hosts. 

Possible values are: 

  • IP address

  • host name

  • ANY

  • any

  • *

Signatures

BG[, BG:

The signatures used by the LCP to collect the necessary log events from the logs generated by the BeyondTrust Remote Support.

If there are more than one signature, then the signatures must be seperated by a comma (,).

If you add a new sensor configuration other than the default one, the Signatures field is empty. Then you must manually enter appropriate signatures. If the Signatures field is empty, the signature based filtering of messages does not happen. 

Enable Signatures

True

 

Port Number

514

The port number to which you have configured to send syslog messages.

 

Legal Notice

Copyright © 2021 Accenture. All rights reserved.

Accenture, the Accenture Logo, and DeepSight Intelligence are trademarks or registered trademarks of Accenture in the U.S. and other countries. Other names may be trademarks of their respective owners.

The product described in this document is distributed under licenses restricting its use, copying, distribution, and decompilation/reverse engineering. No part of this document may be reproduced in any form by any means without prior written authorization of Accenture and its licensors, if any.

THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. ACCENTURE SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE.

The Licensed Software and Documentation are deemed to be commercial computer software as defined in FAR 12.212 and subject to restricted rights as defined in FAR Section 52.227-19 "Commercial Computer Software - Restricted Rights" and DFARS 227.7202, et seq. "Commercial Computer Software and Commercial Computer Software Documentation," as applicable, and any successor regulations, whether delivered by Accenture as on premises or hosted services. Any use, modification, reproduction release, performance, display or disclosure of the Licensed Software and Documentation by the U.S. Government shall be solely in accordance with the terms of this Agreement.