Accenture MDR Quick Start Guide for Symantec Anomaly Detection for Industrial Control Systems

This quick start guide will help Accenture MDR customers configure the Symantec Anomaly Detection (AD) for Industrial Control Systems (ICS) event collector to send logs to the Log Collection Platform (LCP). 

 This document includes the following topics:

 

Supported Versions

A list of supported versions is available in the Accenture MDR Supported Products List document (Accenture_MSS_Supported_Products_List.xlsx) which can be found in Accenture MDR Portal - https://mss.accenture.com/PortalNextGen/Reports/Documents

Port Requirements

Table 1-1: Port requirements for LCP communication.

Source

Destination

Port

Description

ICS Event Collector

LCP 

514 (UDP)

Default port

Configuring ICS Event Collector

To forward event logs to the LCP, the following files need to be configured as required.

  1. Set the syslog server IP address and port.

    1. Go to <install_folder>/symc_ad_industrial/etc/config/log4j.properties

    2. Set log4j.appender.syslog.SyslogHost=<LCP_IP_Address>:514

  2. Enable Syslog Integration. By default, it will be false.

    1. Go to <install_folder>/symc_ad_industrial/etc/config/config.properties

    2. Set SYSLOG.ENABLE = true

  3. Change the syslog update frequency.

    1. Go to <install_folder>/symc_ad_industrial/etc/config/config_internal.properties

    2. Set ALERT_MANAGER.EVENT_LOG_INTERVAL_IN_SECS = 60

LCP Configuration Parameters   

Table 1-2: ICS event collector (Syslog -3820) properties to be configured by MSS are shown in the table.

Property 

Default Value

Description

Protocol

UDP

The default protocol for syslog. At present, only UDP is supported.

IP Address

<Device IP address>

Logging device IP address mentioned in the Pre-Installation Questionnaire (PIQ).

Note: If the device sends logs using multiple interfaces, contact the Accenture Security MSS onboarding team.

Signatures

SymantecAnomalyDetectionICSLog

MSS recommended signatures processed by the ICS event collector.

Port Number

514

The default port for syslog.

Note: The LCP can be configured to listen on a non-standard port, please advise the Accenture Security MSS onboarding

team if this is a requirement.

 

Legal Notice

Copyright © 2021 Accenture. All rights reserved.

Accenture, the Accenture Logo, and DeepSight Intelligence are trademarks or registered trademarks of Accenture in the U.S. and other countries. Other names may be trademarks of their respective owners.

The product described in this document is distributed under licenses restricting its use, copying, distribution, and decompilation/reverse engineering. No part of this document may be reproduced in any form by any means without prior written authorization of Accenture and its licensors, if any.

THE DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. ACCENTURE SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE.

The Licensed Software and Documentation are deemed to be commercial computer software as defined in FAR 12.212 and subject to restricted rights as defined in FAR Section 52.227-19 "Commercial Computer Software - Restricted Rights" and DFARS 227.7202, et seq. "Commercial Computer Software and Commercial Computer Software Documentation," as applicable, and any successor regulations, whether delivered by Accenture as on premises or hosted services. Any use, modification, reproduction release, performance, display or disclosure of the Licensed Software and Documentation by the U.S. Government shall be solely in accordance with the terms of this Agreement.