About the Device

The Nasuni Edge Appliance is a system made to replicate any asset that you put in it, to servers and many geographical locations across data centers. It enables organizations to store, protect, synchronize, and collaborate on unstructured file data across all locations. It is distributed and fully versioned, so you can attach multiple access points to this file system so that you can synchronize workload.

Device Information

 Entity

Particulars

Vendor Name

Nasuni

Product Name

Edge Appliance

Type of Device

Hybrid

Collection Method

Log Type

 Ingestion label

Preferred Logging Protocol

Log collection method

Nasuni File Services Platform

NASUNI_FILE_SERVICES

Syslog (JSON)

CyberHub

Port Requirements

Source

Destination

Port

Vectra

CyberHub

601 (TCP)

Device Configuration

  1. Log in to Nasuni Edge Appliance with Admin credentials

  2. Click Configuration.

  3. Select Syslog Export Configuration

  4. Syslog Exporting Page will appear

image-20240229-110950.png
  1. Provide CyberHub IP and Port into the Servers empty box. Format for providing this detail is as host:port

  2. Adaptive MXDR recommends enabling Send Auditing messages to On.

  3. Select the facility on the Logging Facility and Select the Log Level for Audit messages as Info.

  4. Click on Save.

Integration Parameters

Parameters required from customer for Integration.

Property

Default Value

Description

Protocol

TCP

Preferred protocol.

Host Names/ IP Addresses

*

 Specify the IP addresses or host names. Possible values: IP, hostname, or '*' .

Signatures

AUDIT_CLOSE, AUDIT_READDIR, AUDIT_UTIMENS, AUDIT_WRITE, AUDIT_MKNOD, AUDIT_SETXATTR, AUDIT_TRUNCATE, AUDIT_UNLINK

 Specify the list of signatures (comma-separated list of strings) that are used to filter the incoming syslog

Enable Signatures

True

 Boolean property (represented by a checkbox in UI) that allows you to disable the signature filtering.

Port Number

601

Default port. Provide port which you have configured in the device configuration.