Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

This quick start guide will help Accenture MDR customers configure Airlock Digital to allow log collection from the Log Collection Platform (LCP).

The document includes the following topics:

Supported Versions

A list of supported versions is available in the Accenture MDR Supported Products List document (Accenture_MDR_Supported_Products_List.xlsx) which can be found at Accenture MDR Portal - https://mss.accenture.com/PortalNextGen/Reports/Documents

Port Requirements         

Table 1-1: Port requirements for LCP communication.

Source

Destination

Port

Description

LCP

Airlock Digital

TCP / 443

Default port and protocol

Configuring Airlock Digital

  1. Log in to the Airlock web console - https://<hostname>:3128.

2. Click My Profile under the user name section.

  3. Click Generate API key to create a new.

4. Share the newly generated API key to Accenture MDR Onboarding team to fetch logs.

Note: Generated API key will have admin access and can be used to perform all the actions on the Airlock server. Currently we can not set read-only permission on the API key as per device limitation.

LCP Configuration parameters

Table 1-2: The Airlock Digital collector (API-5013) properties to be configured by MSS are shown in table.

Property

Default Value

 Description

URL

<Custom Value>

Airlock server URL(https://<hostname>:3129)

Note: APIs can be accessed on port 3129 and for server login use port number 3128.

API Key

<Custom Value>

API Key mentioned in the Pre-Installation Questionnaire (PIQ).

API Key generated in Step 3.

 