Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Log Type

 Ingestion label

Preferred Logging Protocol - Format

Log Collection Method

Cylance Protect

CYLANCE_PROTECT

Syslog (KV)

CyberHub

Port Requirements

Source

Destination

Port

Cylance ProtectBlackBerry CylanceENDPOINT

CyberHub

6514 (TLS)

To facilitate secure communication and align with our best practice, we strongly encourage the use of Transport Layer Security (TLS) between your security devices and our Adaptive MxDR platform for event forwarding.

While we understand that TLS support may not be available on all devices, if your devices do support TLS communication, we recommend utilizing port 6514 for seamless integration.

In some cases, the upgraded version of the device might incorporate TLS support without prior notice. If you come across such a scenario or for further assistance in configuring TLS, we kindly ask you to reach out to your dedicated Adaptive MxDR Service Delivery Lead.

Device Configuration

  1. In the management console, on the menu bar, click Settings > Application

  2. Select Syslog/SIEM.

  3. Select the events that you want to send to your organization's SIEM solution or syslog server.

  4. Select or type in the information for your SIEM or syslog integration.

  5. In the SIEM dropdown, click the appropriate SIEM solution or syslog server.

  6. In the Protocol dropdown, click the appropriate protocol. It is a best practice to select the TLS/SSL to ensure that the syslog message is encrypted in transit (verify that your SIEM solution or syslog server is configured to listen for messages).

  7. If you want to include the full contents of fields with command line values, select the Allow messages over 2 KB to ensure that the full file path is populated in the Instigating Process Command Line field of CylanceOPTICS detection events. This setting is only available for CylanceOPTICS.

    If you do not select the above option, the file path in the Instigating Process Command Line field in the CylanceOPTICS detection events are truncated at 120 characters to keep the size of messages under 2 KB.

  8. In the IP/Domain, type the FQDN or IP address of the SIEM solution or syslog server.

  9. In the Port, type the port number that you want the SIEM solution or syslog server to listen on for messages. The port number must be between 1 and 65535.

  10. In the Severity dropdown, click the severity of the messages that should appear in the SIEM solution or syslog server. This value does not change the messages that are sent to the SIEM solution or syslog server.

  11. In the Facility dropdown, click the type of application that is logging the message. This value is used to categorize the messages that are received by the SIEM solution or syslog server.

  12. If necessary, in the Custom Token, type the custom token that your organization’s log management service requires for SIEM or syslog messages.

  13. Click Test Connection to verify that your settings are correct.

  14. Click Save

...

Property

Default Value

Description

IP Address

Cylance Protect BlackBerry CylanceENDPOINT interface IP address

Hostname or IP address of the device which forwards logs to the CyberHub.