Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Source

Destination

Port

i-Filter

CyberHub

10014 (Secure TCP)

Device Configuration

In order to configure the I-Filter proxy software to collect logs in a log file please follow below steps:

To Configure Log Settings /Access Log (For DigitalArts iFilter on Windows Machine):

  1. Login Log in to http://inetnf.conf/ as an Administrator.

  2. In the i-Filter Proxy Server Web Console, navigate to System Setting > Log Settings.

  3. In the Access Log section, specify the following values and click the Save button from the right top corner.

    1. Output Methods: "I-FILTER" standard format

    2. Output path: logs/access.log

...

3.Navigate to Format Settings and select the Default default format as shown.

...

  1. Confirm andclick Save.

  2. Restart the device to reflect the changes done by you.

...

  1. Copy and paste the certificate to new file and save this file into DNS server at desired location.

  2. Navigate to folder C:\Program Files (x86)\nxlog\data and delete configcache.dat.

  3. For Windows Agent, go to installed location C:\Program Files (x86)\nxlog\conf and rename the attached to 

    View file
    namenxlog.conf(Windows_TLS)
    nxlog.conf and copy into this folder.

  4. Replace “lcpip” with “CyberHub IP address” in nxlog.conf.

  5. I-Filter Web Proxy Log (access.log) location needs to be mentioned on line 31 against "File".

  6. Add CAFile location at position 44.

  7. Now start the nxlog service from services.msc.

  8. NxLog agent logs will be available at location C:\Program Files (x86)\nxlog\data\nxlog.log.

...