This quick start guide will help Accenture MDR customers configure F5® BIG-IP Local Traffic Manager (LTM) to send logs to the Log collection Platform (LCP).

...

Table 1-1: Port requirements for LCP communication.

Source

Destination

Port

Description

F5 BIG-IP LTM

LCP

514 (UDP)

Default port

Configuring F5 BIG-IP LTM

...

Table 1-2: The F5 BIG-IP LTM event collector (3371 – Syslog) properties to be configured by MDR are shown in the table.

Property

Default Value

Description

Protocol

UDP

The default protocol for syslog.

Note: F5 LTM does not support TCP.

IP Address

F5 BIG-IP LTM Interface IP address

Logging device IP address mentioned in the Pre-Installation Questionnaire (PIQ).

Note: If the device sends logs using multiple interfaces, contact the Accenture MDR onboarding team.

Port Number

514

The default port for UDP.

Note: The LCP can be configured to listen on a non-standard port, please advise the MDR onboarding team if this is a requirement.